1.
Clin Chem Lab Med ; 61(7): 1131-1132, 2023 06 27.
Article in English | MEDLINE | ID: covidwho-20241371
2.
Clin Chem Lab Med ; 61(8): 1361-1362, 2023 Jul 26.
Article in English | MEDLINE | ID: covidwho-2298924
4.
J Clin Med ; 12(5)2023 Feb 26.
Article in English | MEDLINE | ID: covidwho-2276631

ABSTRACT

Three years after coronavirus disease 2019 (COVID-19) was declared a pandemic by the World Health Organization (WHO), several features of the pathogenesis and innate immune response to SARS-CoV-2 (severe acute respiratory syndrome coronavirus disease 2) have now been clarified [...].

5.
Clin Chem Lab Med ; 61(8): 1506-1510, 2023 Jul 26.
Article in English | MEDLINE | ID: covidwho-2276490

ABSTRACT

OBJECTIVES: Given that SARS-CoV-2 antigen tests will represent a pillar for supporting or surrogating molecular testing in the endemic period, we report here the clinical performance of the new SNIBE Maglumi SARS-CoV-2 antigen fully-automated chemiluminescent immunoassay (MAG-CLIA SARS-CoV-2 Ag). METHODS: The study population consisted of 181 subjects (mean age 61 ± 21 years; 92 females) undergoing coronavirus disease 2019 (COVID-19) testing at the local diagnostic facility, from December 2022 to February 2023. Routine diagnostic practice involved the collection of a double nostril nasopharyngeal swab, analyzed in duplicate with SARS-CoV-2 antigen (MAG-CLIA SARS-CoV-2 Ag) and molecular (Altona Diagnostics RealStar SARS-CoV-2 RT-PCR Kit) tests. RESULTS: A significant Spearman's correlation was found between MAG-CLIA SARS-CoV-2 Ag and mean Ct values of SARS-CoV-2 E and S genes (r=-0.95; p<0.001). In all nasopharyngeal samples, the area under the curve (AUC) of MAG-CLIA SARS-CoV-2 Ag was 0.86 (95% CI, 0.81-0.90), with 0.71 sensitivity and 1.00 specificity at 7 ng/L cut-off, increasing to 0.98 (95% CI, 0.96-1.00) AUC and 0.96 sensitivity (with 0.97 specificity) in high viral load samples. When SARS-CoV-2 N protein concentration was replaced with raw instrumental readings (i.e., relative light units [RLU]), the AUC in all samples increased to 0.94. A RLU value of 945 was associated with 88.4% accuracy, 0.85 sensitivity, 0.95 specificity, 0.77 negative predictive value (NPV) and 0.97 positive predictive value (PPV), respectively. CONCLUSIONS: We found satisfactory analytical performance of MAG-CLIA SARS-CoV-2 Ag, which could be used as surrogate of molecular testing for identifying high viral load samples. Broadening the reportable range of values may generate even better performance.


Subject(s)
COVID-19 , SARS-CoV-2 , Female , Humans , Adult , Middle Aged , Aged , Aged, 80 and over , COVID-19/diagnosis , Immunologic Tests , Area Under Curve , Immunoassay , Sensitivity and Specificity
6.
Clin Chem Lab Med ; 61(9): 1652-1660, 2023 Aug 28.
Article in English | MEDLINE | ID: covidwho-2255679

ABSTRACT

OBJECTIVES: The SARS-CoV-2 immune response is mediated by both humoral and cellular immunity. In this study, SARS-CoV-2 specific cellular immunity was tested by a novel direct real-time PCR (dRT-PCR) assay, targeting mRNA of CXCL10, and compared with respect to an ELISA measuring interferon gamma (IFN-γ) release. METHODS: Whole blood (Li-He) and serum samples were collected from 92 healthcare workers (HCW), with three doses of homologous (Pfizer/BioNTech, n=74) or heterologous (Pfizer/BioNTech and Vaxzevria or Moderna, n=18) vaccinations. Li-He samples were incubated with SCV2 PANEL-1-T-ACTIVATION (Hyris srl, Lodi, Italy), or CoV-2 IGRA TUBE ELISA (Euroimmune, Lubeck, Germany). CXCL10 mRNA expression was analyzed by bCube/bApp (Hyris), while IFN-γ was evaluated by quant-T-Cell SARS-CoV-2 ELISA (Euroimmune). Anti-SARS-CoV-2 S-RBD IgG levels were measured in sera using a CLIA assay (Snibe, Shenzen, China). RESULTS: Imprecision of dRT-PCR assay was found to be satisfactory, and the two methods for measuring T cell immunity to SARS-CoV-2 peptides agreed in 82/87 (94.2%) of results. At qualitative dRT-PCR analyses, 81 subjects (93.2%) resulted as reactive to SARS-CoV-2 peptides, 3 (3.4%) were borderline and 3 were negative (3.4%). At univariate and multivariate analyses of quantitative dRT-PCR mRNA of CXCL10 and IFN-γ release results showed no difference between HCW with previous infection, homologous/heterologous vaccination, or demographical features. Anti-SARS-CoV-2 S-RBD IgG was associated with the previous infection and the time between the last vaccination or positivity. CONCLUSIONS: Direct RT-PCR appeared accurate for determining the presence or absence of immunoreactivity of SARS-CoV-2 specific T cells, especially when rapid analyses are required, such as for organ transplantation.


Subject(s)
COVID-19 , T-Lymphocytes , Humans , COVID-19 Vaccines , Real-Time Polymerase Chain Reaction , COVID-19/diagnosis , COVID-19/prevention & control , SARS-CoV-2 , Vaccination , Lithium , Immunoglobulin G , Antibodies, Viral , COVID-19 Testing
7.
Clin Chem Lab Med ; 2022 Nov 24.
Article in English | MEDLINE | ID: covidwho-2258854

ABSTRACT

This review is an integral part of the special issue for the 60 years of the journal Clinical Chemistry and Laboratory Medicine (CCLM). The aim of the review is to highlight the role of the clinical laboratory since the emergence of the "severe acute respiratory syndrome coronavirus 2" (SARS-CoV-2), which causes Coronavirus disease 2019 (COVID-19), with special focus on the contribution of the journal in generating knowledge in SARS-CoV-2 diagnosis. As of October 30, 2022, a total of 186 CCLM publications were dedicated to COVID-19. Of importance, major International Federation of Clinical Chemistry (IFCC) guidelines related to the diagnosis of COVID-19 were published in CCLM. Between early-2020 and late October 2022, COVID-19 publications represented around 27% of all articles in CCLM, highlighting the willingness of the editorial board to help the field in order to better describe and diagnose this new emerging disease. First launched in 1963 under the name "Zeitschrift für Klinische Chemie", the Journal was entirely devoted to clinical chemistry in the strict sense. The various topics published in relation to COVID-19 including its diagnosis, its impact on biochemical or hematological measures, as well as biosafety measures, is the perfect example that shows that the journal has greatly diversified over time.

9.
Eur J Intern Med ; 2022 Nov 23.
Article in English | MEDLINE | ID: covidwho-2242768
10.
Clin Chem Lab Med ; 61(9): 1540-1545, 2023 Aug 28.
Article in English | MEDLINE | ID: covidwho-2234457

ABSTRACT

C-reactive protein (CRP) is an acute-phase protein which is synthesized by the liver in response to the secretion of several inflammatory cytokines including interleukin 6 (IL-6), IL-1 and tumor necrosis factor (TNF). CRP was the first acute-phase protein to be described and adopted in clinical laboratories as an exquisitely sensitive systemic marker of inflammation and tissue damage. The measurement of CRP is widely used for the diagnosis and monitoring of inflammatory conditions, including sepsis, trauma, and malignancies. In the last decades, impressive advances in analytical methods (from qualitative to high-sensitivity assays), automation and availability of results in a short time, not only translated in an increasing demand for the right management of systemic inflammatory diseases, but also in evaluating subclinical inflammatory processes underlying atherothrombotic events. CRP measurement is one of the most requested laboratory tests for both the wide range of clinical conditions in which it may assure a valuable information and some analytical advantages due to the evidence that it is a "robust biomarker". Even recently, the measurement of CRP received new interest, particularly as a biomarker of severity of Coronavirus disease 2019 (COVID-19), and it deserves further concern for improving demand appropriateness and result interpretation.


Subject(s)
C-Reactive Protein , COVID-19 , Humans , C-Reactive Protein/metabolism , Laboratories, Clinical , COVID-19/diagnosis , Biomarkers , Acute-Phase Proteins
11.
Clin Chem Lab Med ; 2022 Nov 11.
Article in English | MEDLINE | ID: covidwho-2234458
12.
Clin Chem Lab Med ; 2022 Nov 08.
Article in English | MEDLINE | ID: covidwho-2232584

ABSTRACT

Due to the many technical limitations of molecular biology, the possibility to sustain enormous volumes of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) diagnostic testing relies strongly on the use of antigen rapid diagnostic tests (Ag-RDTs). Besides a limited analytical sensitivity, the manually intensive test procedures needed for performing these tests, very often performed by unskilled personnel or by the patients themselves, may contribute to considerably impair their diagnostic accuracy. We provide here an updated overview on the leading preanalytical drawbacks that may impair SARS-CoV-2 Ag-RDT accuracy, and which encompass lower diagnostic sensitivity in certain age groups, in asymptomatic subjects and those with a longer time from symptoms onset, in vaccine recipients, in individuals not appropriately trained to their usage, in those recently using oral or nasal virucidal agents, in oropharyngeal swabs and saliva, as well as in circumstances when instructions provided by the manufacturers are unclear, incomplete or scarcely readable and intelligible. Acknowledging these important preanalytical limitations will lead the way to a better, more clinically efficient and even safer use of this important technology, which represents an extremely valuable resource for management of the ongoing pandemic.

13.
Clin Chem Lab Med ; 2022 Oct 26.
Article in English | MEDLINE | ID: covidwho-2230177

ABSTRACT

OBEJCTIVES: Serosurveys can be used to monitor COVID-19 seroprevalence and conduct surveillance. Dried blood spot (DBS), used increasingly as a valuable sample to assay severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) antibodies (Ab), has several advantages, particularly in infants, due to the limited amount of blood required and its utility in testing a large number of samples in a limited time-frame. We evaluated SARS-CoV-2 IgG Ab prevalence in newborn DBS in the Trentino region of Italy, during the time period January 2020 - December 2021. METHODS: Anti-SARS-CoV-2 IgG levels were determined in DBS by means of Anti-SARS-CoV-2 QuantiVac IgG ELISA assay (Euroimmun, Lubeck, Germany). RESULTS: Analyses included 2,400 DBS from newborns (54% M, 46% F), samples being collected 2-3 days after birth. The first DBS that tested positive for anti-SARS-CoV-2 IgG antibodies was found in March 2020 and, up to May 2020, only 4 positive results were detected overall. Starting from June 2020, the positivity thresholds increased according to the epidemiological waves of the COVID-19 pandemic in Italy, with a robust increment in the winters of 2020 and 2021. The percentage of positive DBS rose from 0 to 6% to 10-47%, in 2020 and 2021, respectively. CONCLUSIONS: This study demonstrates DBS is a suitable tool for both epidemiological purposes and surveillance in the SARS-CoV-2 pandemic, particularly in newborns and pregnant women, saving blood waste and sparing patients any discomfort.

14.
Clin Chem Lab Med ; 2022 Oct 26.
Article in English | MEDLINE | ID: covidwho-2227164

ABSTRACT

OBJECTIVES: The rapid, accurate and safe detection of SARS-CoV-2 is the key to improving surveillance and infection containment. The aim of the present study was to ascertain whether, after heat/chemical inactivation, SARS-CoV-2 N antigen chemiluminescence (CLEIA) assay in saliva remains a valid alternative to molecular testing. METHODS: In 2022, 139 COVID-19 inpatients and 467 healthcare workers were enrolled. In 606 self-collected saliva samples (Salivette), SARS-CoV-2 was detected by molecular (TaqPath rRT-PCR) and chemiluminescent Ag assays (Lumipulse G). The effect of sample pre-treatment (extraction solution-ES or heating) on antigen recovery was verified. RESULTS: Salivary SARS-CoV-2 antigen assay was highly accurate (AUC=0.959, 95% CI: 0.943-0.974), with 90% sensitivity and 92% specificity. Of the 254 antigen positive samples, 29 were false positives. We demonstrated that heterophilic antibodies could be a cause of false positive results. A significant antigen concentration decrease was observed after ES treatment (p=0.0026), with misclassification of 43 samples. Heat had a minimal impact, after treatment the correct classification of cases was maintained. CONCLUSIONS: CLEIA SARS-CoV-2 salivary antigen provides accurate, timely and high-throughput results that remain accurate also after heat inactivation, thus ensuring a safer work environment. This supports the use of salivary antigen detection by CLEIA in surveillance programs.

15.
Clin Chem Lab Med ; 61(7): 1343-1348, 2023 06 27.
Article in English | MEDLINE | ID: covidwho-2224507

ABSTRACT

OBJECTIVES: This study investigated the feasibility and clinical value of using a novel, automated and high-throughput SARS-CoV-2 Interferon Gamma Release Assay (IGRA), combined with total anti-SARS-CoV-2 antibodies assessment, for evaluating the immune response after bivalent BNT162b2 vaccination. METHODS: A cohort of healthcare workers, who already underwent primary vaccination and boosting with monovalent BNT162b2 vaccine, received a booster dose of the new BNT162b2 bivalent formulation. Blood samples were taken immediately before vaccination (T0) and 1 month afterwards (T1). Humoral and cellular immunity were assayed with Roche Elecsys Anti-SARS-CoV-2 and Roche Elecsys IGRA SARS-CoV-2, respectively. RESULTS: The study population consisted of 51 subjects (median age: 43 years; 51% females). Total anti-SARS-CoV-2 antibodies and IGRA SARS-CoV-2 values increased at T1 from 9,050 to 25,000 BAU/mL (p<0.001), and from 0.44 to 0.78 IU/mL (p=0.385), accounting for median increase of 2.0 and 1.6 folds, respectively. Increased T1 values of total anti-SARS-CoV-2 antibodies and IGRA SARS-CoV-2 were recorded in 100% and 68.6% subjects, respectively. In those with baseline values below the median, post-vaccine levels displayed larger increases of 3.3 and 5.1 folds for anti-SARS-CoV-2 total antibodies and IGRA SARS-CoV-2, respectively. The variation of total anti-SARS-CoV-2 antibodies was inversely associated with their T0 values (r=-0.97; p<0.001), whilst that of IGRA SARS-CoV-2 was inversely associated with its T0 value (r=-0.58; p<0.001). No other signifcant associations were found with demographical or clinical variables, including side effects. CONCLUSIONS: The bivalent BNT162b2 vaccine booster enhances humoral and cellular immunity against SARS-CoV-2, especially in recipients with lower baseline biological protection.


Subject(s)
BNT162 Vaccine , COVID-19 , Female , Humans , Adult , Male , COVID-19/prevention & control , SARS-CoV-2 , Vaccination , Immunity, Cellular , Antibodies, Viral
16.
J Clin Med ; 11(7)2022 Mar 24.
Article in English | MEDLINE | ID: covidwho-2225352

ABSTRACT

Several studies shed light on the interplay among inflammation, thrombosis, multi-organ failures and severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection. Increasing levels of both free and/or circulating histones have been associated to coronavirus disease 2019 (COVID-19), enhancing the risk of heart attack and stroke with coagulopathy and systemic hyperinflammation. In this view, by considering both the biological and clinical rationale, circulating histones may be relevant as diagnostic biomarkers for stratifying COVID-19 patients at higher risk for viral sepsis, and as predictive laboratory medicine tool for targeted therapies.

17.
Clin Chem Lab Med ; 61(7): 1133-1139, 2023 06 27.
Article in English | MEDLINE | ID: covidwho-2197307

ABSTRACT

BACKGROUND: This article provides a critical literature review and pooled analysis of diagnostic accuracy of the fully-automated Siemens SARS-CoV-2 Antigen (CoV2Ag) chemiluminescent immunoassay for diagnosis of acute SARS-CoV-2 infections. METHODS: An electronic search was conducted in Scopus, PubMed and medRxiv using the keywords ["Siemens AND CoV2Ag"] OR ["Siemens AND SARS-CoV-2 AND antigen"] for capturing studies that investigated the accuracy of Siemens CoV2Ag for diagnosing acute SARS-CoV-2 infection against a reference SARS-CoV-2 molecular test. The retrieved information was used for constructing a 2 × 2 table and for calculating pooled diagnostic sensitivity, specificity, Summary Receiver Operating Characteristic Curve (SROC) and Agreement. This study followed the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) reporting checklist. RESULTS: Four studies totalling 1,310 respiratory samples (612 with high viral load) were finally included in our analysis. The cumulative area under the curve, accuracy, sensitivity, specificity, were 0.964 (95% CI, 0.957-0.971), 86.9% (95% CI, 84.9-88.7%), 0.79 (95% CI, 0.76-0.82) and 0.98 (95% CI, 0.96-0.99), respectively. The negative (NPV) and positive (PPV) predictive values were 0.77 (0.74-0.79) and 0.98 (95% CI, 0.96-99), respectively. The diagnostic sensitivity in samples with high viral load (i.e., Ct<29-30) was 0.95 (95% CI, 0.93-0.97). CONCLUSIONS: The Siemens CoV2Ag fully-automated and high-throughput immunoassay approximates the minimum performance criteria for general SARS-CoV-2 antigen testing and displays excellent performance in samples with high viral load, thus representing a valuable screening solution for risk assessment in COVID-19 and for limiting viral spread.


Subject(s)
COVID-19 , Humans , COVID-19/diagnosis , SARS-CoV-2 , COVID-19 Testing , Sensitivity and Specificity , Immunoassay
18.
Clin Chem Lab Med ; 61(6): 960-973, 2023 05 25.
Article in English | MEDLINE | ID: covidwho-2197300

ABSTRACT

The SARS-CoV-2 infection is characterized by both systemic and organ hyper-thromboinflammation, with a clinical course ranging from mild up-to critical systemic dysfunction and death. In patients with coronavirus disease 2019 (COVID-19) the monocyte/macrophage population is deeply involved as both trigger and target, assuming the value of useful diagnostic/prognostic marker of innate cellular immunity. Several studies correlated morphological and immunophenotypic alterations of circulating monocytes with clinical outcomes in COVID-19 patients, concluding that monocyte distribution width (MDW) may retain clinical value in stratifying the risk of disease worsening. Through an electronic search in Medline and Scopus we performed an updated literature review and meta-analysis aimed to explore the association between increased MDW levels and illness severity in COVID-19 patients, deciphering role(s) and function(s) of monocytes in the harmful network underlining SARS-CoV-2 infection. We found that significantly elevated MDW values were frequently present in COVID-19 patients who developed unfavorable clinical outcomes, compounded by a significant association between monocyte anisocytosis and SARS-CoV-2 outcomes. These findings suggest that blood MDW index and its scatter plot could represent useful routine laboratory tools for early identification of patients at higher risk of unfavorable COVID-19 and for monitoring the progression of viral infection, clinical outcomes, and therapeutic efficacy throughout hospitalization. According to this evidence, therapeutic decisions in patients with SARS-CoV-2 infection could benefit from monitoring MDW value, with administration of drugs limiting thrombo-inflammation due to monocyte hyper-activation in patients with severe/critical COVID-19 disease.


Subject(s)
COVID-19 , Thrombosis , Humans , Monocytes , SARS-CoV-2 , Inflammation
19.
Vaccines (Basel) ; 11(1)2023 Jan 05.
Article in English | MEDLINE | ID: covidwho-2167057

ABSTRACT

This study is aimed at developing a simple epidemiologic model that could help predict the impaired neutralization of new SARS-CoV-2 variants. We explored the potential association between neutralization of recent and more prevalent SARS-CoV-2 sublineages belonging to the Omicron family (i.e., BA.4/5, BA.4.6, BA.2.75.2, BQ.1.1 and XBB.1) expressed as FFRNT50 (>50% suppression of fluorescent foci fluorescent focus reduction neutralization test) in recipients of four doses of monovalent mRNA-based coronavirus disease 2019 (COVID-19) vaccines, with epidemiologic variables like emergence date and number of spike protein mutations of these sublineages, cumulative worldwide COVID-19 cases and cumulative number of COVID-19 vaccine doses administered worldwide at the time of SARS-CoV-2 Omicron sublineage emergence. In the univariate analysis, the FFRNT50 value for the different SARS-CoV-2 Omicron sublineages was significantly associated with all such variables except with the number of spike protein mutations. Such associations were confirmed in the multivariate analysis, which enabled the construction of the equation: "−0.3917 × [Emergence (date)] + 1.403 × [COVID-19 cases (million)] − 121.8 × [COVID-19 Vaccine doses (billion)] + 18,250", predicting the FFRNT50 value of the five SARS-CoV-2 Omicron sublineages with 0.996 accuracy (p = 0.013). We have shown in this work that a simple mathematical approach, encompassing a limited number of widely available epidemiologic variables, such as emergence date of new variants and number of COVID-19 cases and vaccinations, could help identifying the emergence and surge of future lineages with major propensity to impair humoral immunity.

20.
EJIFCC ; 33(2):94-104, 2022.
Article in English | EuropePMC | ID: covidwho-2092683

ABSTRACT

Background Quantification of SARS-CoV-2 antigens by means of rapid, high-throughput and fully-automated techniques has been proposed as a feasible alternative to overcome the current shortage of resources for routine molecular diagnostics. To this end, we provide here a systematic review of diagnostic accuracy of DiaSorin Liaison SARS-CoV-2 antigen immunoassay. Methods An electronic search was conduced in Medline and Scopus, with no language or date restrictions (up to January 20, 2022), for identifying all published studies articles in which the diagnostic performance of the DiaSorin Liaison SARS-CoV-2 antigen immunoassay was compared with molecular diagnostic techniques. Results The electronic search identified a final number of 11 studies, totalling 4449 oro- and naso-pharyngeal specimens. The pooled diagnostic sensitivity, specificity and area under the curve (AUC) of the Liaison SARS-CoV-2 antigen immunoassay in all samples were 0.51 (95%CI, 0.49-0.54), 1.00 (95%CI, 1.00-1.00) and 0.994 (95%CI, 0.990-0.998), respectively, whilst the overall concordance with molecular diagnostics was 82.1%. The pooled diagnostic sensitivity, specificity and AUC of the Liaison SARS-CoV-2 antigen immunoassay in specimens with high viral load (i.e., cycle threshold values <25-30) were 0.79 (95%CI, 0.75-0.82), 1.00 (95%CI, 0.99-1.00) and 0.911 (95%CI, 0.879-0.943), respectively, whilst the overall concordance with molecular diagnostics in such samples increased to 94.2%. Conclusion The results of this systematic literature review suggest that there is sufficient accuracy of the DiaSorin Liaison SARS-CoV-2 antigen immunoassay in samples with high viral loads that would enable its reliable usage for identifying superspreaders, who are responsible for the vast majority of transmission events.